 Shop our Online Store!
 Swine Production Systems Brochure |
| Infraconic Radiant Heater Specifications
|
|
| |
Infraconic
I-10
|
Infraconic
I-17
|
Infraconic
I-3
|
Infraconic
I-5
|
| Heat Rating |
| Btu/h Rating (Btu/h) |
10,400 |
17,100 |
2,800 |
5,200 |
| Pig Coverage |
| Farrowing | - |
- |
1 unit per 2 crates |
- |
| Nursery/Wean to Finish | 150 |
170 |
- |
30 |
| Configurations Available |
| Modulating | Yes |
Yes |
Yes |
Yes |
| Spark Ignition | Yes |
Yes |
- |
- |
| Installation Height |
| Installation Height (ft.) |
4 |
5 |
2 |
3 |
| Fuel Consumption (max) |
| LPG (lbs./hr.) |
0.48 |
0.80 |
0.16 |
0.24 |
| NG (cu. ft./hr.) |
10.4 |
17.1 |
3.4 |
5.2 |
| Inlet Gas Pressure |
| LPG (PSIG) |
5 |
5 |
5 |
5 |
| NG (PSIG) |
5 |
5 |
5 |
5 |
| Ventilation Requirements |
| Ventilation (CFM) |
122 |
200 |
40 |
60 |
| Temperature Controls Available |
| Individual Thermostat | Modulating only |
Modulating only |
- |
- |
| Wired to House Control | Yes |
Yes |
- |
Yes |
| Zone (panel sold separately) | Yes |
Yes |
Yes |
Yes |
| Electrical Supply |
| Electrical Requirements - Modulating (Volts/Hz) |
None |
None |
None |
None |
| Electrical Requirements - Spark (Volts/Hz) |
115 / 60 |
115 / 60 |
- |
- |
| Minimum Clearance to Combustibles |
| Below (ft.) |
3.5 |
3.5 |
2.0 |
3.0 |
| Sides (ft.) |
3 |
3 |
2.5 |
3 |
| Top (ft.) |
3 |
3 |
2.5 |
2.5 |
| Dimensions |
| Canopy Diameter (in.) |
16.9 |
16.9 |
7.7 |
11.8 |
| Height (in.) |
8.8 |
8.8 |
4.7 |
5.0 |
| Weight |
| Net Weight (lbs.) |
5.6 |
5.6 |
1.4 |
1.7 |
| Add'l Features/Options |
| Gas Hose - 1/4" x 6 ft | Std. |
Std. |
Std. |
Std. |
| Inlet Air Filter - Spark | Std. |
Std. |
Std. |
Std. |
| Regulator (Zone Control Panel) | Opt. |
Opt. |
Opt. |
Opt. |
|
|
|